Product Details:
| Minimum Order Quantity | 10 Piece |
| Height | 80 Inch |
| Material | Stainless Steel |
| Color | Blue |
| Country of Origin | Made in India |
Lead Lined Doors are specially engineered radiation protection doors designed for rooms where X-ray, CT scan, gamma radiation, or nuclear medicine equipment is used. These doors prevent harmful radiation leakage and ensure the safety of medical staff, patients, and technicians. They are widely used in hospitals, diagnostic centers, laboratories, research facilities, and industrial radiography rooms.
⭐ 1. ConstructionDoor Type:
Single Leaf / Double Leaf
Swing Type / Sliding Type (manual or automatic)
Material of Construction (MOC):
SS 304 / SS 316 (for hospital-grade hygiene)
GI Powder-Coated Steel
Flush laminated door options
Door Leaf Thickness:
45mm to 55mm (depending on lead thickness)
Core:
Solid core with lead sheet inserted across full height and width
Lead Thickness Options:
1 mm, 1.5 mm, 2 mm, 3 mm, up to 10 mm (as per radiation load)
Frame:
Heavy-duty GI/SS frame with full lead lining
Lead sheet is sandwiched inside the door and frame
Complete overlapping ensures zero radiation leakage
Compliant with:
Atomic Energy Regulatory Board (AERB)
IAEA Radiation Safety Standards
ISO and GMP norms (option)
Stainless steel (SS 304/316) – hospital-grade hygienic finish
Powder-coated GI sheet
PVC laminated surface
Antibacterial and scratch-resistant coating
X-ray shielded lead glass with equivalent lead protection
Double-glazed clean finish
SS or powder-coated frame
Heavy-duty SS hinges
SS lockset / radiation-safe lock
SS push-pull handle / D-handle
Door closer (optional)
Kick plate (optional)
Lead-lined frame, architrave, and hardware mounting area
High-performance radiation shielding
Durable, hygienic, and corrosion-resistant
Smooth, easy-to-clean hospital-grade finish
Matching lead lining in door, frame, and vision panel
Strong structural stability for heavy lead-weighted doors
Fire-rated lead-lined doors available on request
X-Ray rooms
CT scan rooms
Cath labs
MRI support rooms (non-magnetic SS options)
Radiology & fluoroscopy rooms
Dentistry clinics with X-ray units
Industrial radiography test rooms
Nuclear medicine facilities
Lead Sheet Purity: 99.99% pure
Lead Thickness: 1mm–10mm
Frame Thickness: 1.2mm–1.6mm GI/SS
Door Leaf Thickness: 45mm–55mm
Radiation Protection: As per AERB recommendations
Glass: Lead equivalent safety glass (1.5–10mm lead)
Additional Information:
Product Details:
| Minimum Order Quantity | 5 Square Meter |
| Material | PCGI |
| Color | White |
| Usage/Application | industrial |
| Country of Origin | Made in India |
| material 2 | GI |
Additional Information:
Product Details:
| Minimum Order Quantity | 5 Piece |
| Material | PCGI |
| Usage/Application | Hospital |
| Color | White |
| Size/Dimension | 1200X2100 |
| Door Open Style | Hinged |
| Country of Origin | Made in India |
Additional Information:
Product Details:
| Material | Powder-Coated GI |
| Height | 8-10 ft |
| Frame Material | MS |
| Type | Double Door |
| Usage/Application | Commercial |
| Color | Blue |
| Open Style | Hinged |
| Surface Finishing | Powder Coated |
| Thickness | 25-30 mm |
| Brand | Lennox |
| Width | 3-5 ft |
Scientific doors are specially engineered to meet the demanding requirements of laboratories, cleanrooms, and other controlled environments. They’re not just about access—they’re about safety, precision, and environmental control. Here's a breakdown of their key uses:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | Hospital |
| Frame Material | GPSP |
| Size/Dimension | 750-4000 |
| Door Open Style | Hinged |
| Type | Hinged Type Door |
| Material Grade | GPSP |
| Surface Finishing | Powder Coated |
| Color | Blue |
| Features | Single & Double glazed Vision Glass, Provision for receiving all hardware |
| Design | Customized |
| Infill | Honeycomb & Puff |
| Brand | Lennox |
| Thickness | 0.8, 1 |
| Glass Type | Toughened |
| Height | 2300 mm- 3000 mm |
| Country of Origin | Made in India |
| Built type | Modular |
Product Details:
| Minimum Order Quantity | 10 Piece |
| Material | PCGI |
| Brand | Lennox |
| Usage/Application | Hospital |
| Color | Blue |
| Height | 7-9 ft |
| Surface | powder Coated |
| Country of Origin | Made in India |
| Built type | Modular |
| type | Hinged |
Product Details:
| Material | PCGI |
| Usage/Application | Hospital |
| Color | White |
| Size/Dimension | 1200 x 2100 mm |
| Door Open Style | Hinged |
| Type | Modular OT Door |
| Infill | Honeycomb Paper Craft |
A Modular OT Door is a hermetic, smooth-surfaced, easy-to-clean door constructed from high-quality materials such as stainless steel or powder-coated steel. It is designed to prevent contamination, ensure proper sealing, maintain positive pressure inside the OT, and support the workflow of medical staff.
�� Key Features 1. Hermetically Sealed / AirtightEnsures minimal air leakage.
Maintains positive pressure to keep contaminants out.
Essential for maintaining sterile conditions.
Made of SS 304 stainless steel, GI powder-coated steel, or HPL (High-Pressure Laminate).
Non-porous and antimicrobial surfaces that prevent bacterial growth.
Easy to clean and disinfect.
Door sits level with the wall panels, eliminating dust traps.
Enables seamless movement of stretchers, equipment, and staff.
Tempered or laminated safety glass.
Ensures privacy with visibility.
Often double-glazed for insulation and safety.
Available as:
Sliding doors (most common in OTs)
Swing doors
Automatic doors often include:
Motion sensors
Foot/Elbow switches
Touchless operation (hygienic)
Controller for opening/closing speed
Smooth and silent mechanism.
Lightweight yet sturdy design for effortless operation.
Doors can be made fire-resistant to protect life and equipment in emergencies.
Special rubber/EPDM gaskets around the edges.
Prevent leakage of conditioned air and preserve room pressure.
Material: SS 304, HPL, or GI powder-coated panels
Door Thickness: 40–50 mm
Glass: 6–12 mm toughened / double glazed
Insulation: Mineral wool / PUF
Operation: Manual or sensor-based automatic
Type: Sliding (most hygienic) or hinged
They help ensure:
Infection control
Proper airflow and pressure zoning
Safety and hygiene
Easy movement of medical equipment