Product Details:
| Minimum Order Quantity | 25 Square Meter |
| Material | GI |
| Door Type | Fireproof |
| Brand | LENNOX CLEAN AIR TECHNOLOGIES |
| Usage/Application | EMERGENCY EXIT DOORS |
| Open Style | Hinged |
| Finish | Powder Coated |
| Sheet Thickness | 1.2 |
| Shutter Thickness | 1.6 |
An Operator Protection LAF Unit is a workstation that uses HEPA-filtered laminar airflow, combined with air containment and exhaust filtration, to create a safe environment for handling hazardous or potent materials. The unit ensures the operator is not exposed to harmful airborne particles generated during the process.
It is commonly used for operations such as weighing, sampling, dispensing, or transferring powders.
�� Key Characteristics 1. Operator Safety Through Negative Pressure ContainmentMaintains negative pressure inside the working zone.
Ensures any aerosol or airborne particle moves into the system—not toward the user.
Protects the operator from exposure to potent compounds.
Supply air passes through HEPA H13/H14 filters to create clean, laminar airflow.
Exhaust air is also HEPA-filtered before release to the room or duct.
Ensures hazardous particles do not escape.
Provides a smooth, controlled airflow (0.3–0.5 m/s).
Minimizes turbulence, reducing the spread of airborne particulate.
Helps create a high level of cleanliness inside the work zone.
Transparent front sash or sliding window for visibility.
Stainless steel or powder-coated interior for easy cleaning.
Adequate space for weighing and handling materials.
Ensures comfortable and safe working conditions.
Important for precise weighing operations.
Built-in LED lights for clear visibility.
Provision for electrical sockets and safe operation of equipment.
Meets industry standards such as:
GMP (Good Manufacturing Practice)
ISO 14644 (Cleanrooms)
OSHA and local safety norms
EU/WHO guidelines
Pre-filter (G4/M5)
HEPA filter (H13/H14)
Blower-motor assembly
Worktable (SS 304)
Glass/sash front panel
Negative pressure chamber
Magnehelic gauge for pressure monitoring
LED lighting
Optional UV-C germicidal lamp
Protects operator from toxic airborne particles
Maintains clean, controlled environment
Effective containment without a full biosafety cabinet
Energy-efficient and easy to maintain
Suitable for cleanrooms and GMP facilities
Additional Information:
Product Details:
| Minimum Order Quantity | 20 Piece |
| Height | 84 Inch |
| Door Type | Double Door |
| Finish | Powder Coated |
| Country of Origin | Made in India |
| Material | GI |
Additional Information:
Product Details:
| Minimum Order Quantity | 5 Piece |
| Material | GI |
| Door Type | Single Door |
| Finish | Powder Coated |
| Brand | LENNOX |
| Country of Origin | Made in India |
Additional Information:
Product Details:
| Minimum Order Quantity | 10 Piece |
| Material | Galvanized Steel |
| Door Type | Fireproof |
| Brand | LENNOX |
| Features | 120 Minutes Fire Resistance |
| Usage/Application | Fire Resistance |
| Open Style | Hinged |
| Finish | Powder Coated |
| Sheet Thickness | 1.6 |
| Country of Origin | Made in India |
Additional Information:
Product Details:
| Minimum Order Quantity | 10 Piece |
| Fire Rating | 120 min |
| Door Type | Double Leaf |
| Material | Galvanized Steel |
| Door Thickness | 46 mm |
| Infill Material | Rockwool |
| Frame Sheet Thickness | 1.2 mm |
| Shutter Sheet Thickness | 0.8 mm |
| Finish | Powder Coated |
| Vision Panel | Yes |
| Hardware Included | Handles, Flush Bolt, Lockset, Door Closer, Panic Bar, External Trim, Hinges |
| BRAND | Lennox |
A Fire Rated Door is a specially engineered safety door designed to resist fire, smoke, and heat for a certified duration, helping prevent the spread of fire between building compartments. These doors ensure safe evacuation and compliance with fire safety regulations in commercial, industrial, and residential buildings.
1. ConstructionType: Single Leaf / Double Leaf Fire Rated Door
Fire Rating Options:
60 minutes
90 minutes
120 minutes
(Tested as per BS 476 Part 22 / IS 3614 / NBC norms)
Leaf Thickness: 46 mm to 50 mm
Frame Material:
1.2 mm – 1.6 mm GI sheet (powder-coated)
Shutter Material:
0.8 mm – 1.2 mm GI sheet (powder-coated finish)
Core Material:
Honeycomb / Mineral Wool / Ceramic Wool (as per rating)
Fire-resistant construction prevents spread of flame and smoke
Intumescent fire seal expands under heat
Smoke protection and thermal insulation
Durable powder-coated surface (any RAL colour)
Heavy-duty fire-rated hardware
Compatible with access control, EM locks, and panic bars
Smooth and silent operation
Fire-rated stainless steel hinges
Door closer (fire-rated)
Panic bar (crash bar)
SS lever handle / pull handle
Fire-rated vision glass (clear or wired)
Drop-down seal
Electromagnetic lock
Door stopper / floor spring
Single leaf fire door
Double leaf fire door
Fire-rated emergency exit door
Fire-rated cleanroom door
Fire-rated shaft / service room door
Fire-rated glass panel door
Hospitals & operation theatres
Pharma & cleanrooms
Commercial buildings
Malls, multiplexes, hotels
Industries & warehouses
Server rooms / electrical rooms / UPS rooms
Staircases & emergency exits
Product Details:
| Minimum Order Quantity | 10 Square Meter |
| Material | GI |
| Fire Resistant | 120 minutes |
| Door Thickness | 46mm |
| Open Style | Hinged |
| Size/Dimension | 1200 x 2100mm |
| Country of Origin | Made in India |
| Brand | Lennox |
An Emergency Exit Door is a specially designed safety door used to provide a quick, unobstructed escape route during emergencies such as fire, power failure, gas leaks, or other hazardous situations. These doors are built to meet safety standards and ensure fast evacuation from industrial, commercial, and institutional buildings.
⭐ 1. ConstructionDoor Type: Single-leaf / Double-leaf
Material Options:
GI Powder-Coated Steel (standard)
SS 304 (optional for cleanrooms)
Door Thickness:
45mm to 50mm
Frame Material:
GI/SS with rubber gasket for noise and smoke reduction
Finish:
Thermoset powder-coated (RAL colors available)
Anti-corrosion treated surface
Panic Bar / Panic Exit Device
Allows quick push-to-open operation
Heavy-Duty Hinges
Stainless steel ball-bearing type
Door Closer
Optional hydraulic closer
Vision Panel (Optional):
Fire-rated glass or clear toughened glass
Drop Seal / Bottom Seal
Lever handles / Emergency push plates (optional)
Quick-release panic bar mechanism
Self-closing and self-latching (when door closers are used)
Smoke-resistant seals
Anti-slip threshold
Glow-in-the-dark signage (Exit symbol)
Can be integrated with Fire Alarm / Access Control Systems
Emergency exit doors can be supplied with certified fire ratings:
30 minutes
60 minutes
90 minutes
120 minutes
(Depending on core material: honeycomb, mineral wool, ceramic wool.)
⭐ 5. Technical SpecificationsCore Options: Honeycomb / Rockwool
Door Leaf Thickness: 45–50 mm
Opening Mechanism: Push bar / panic latch
Frame Profile: 1.2mm – 1.6mm GI or SS
Door Leaf Sheet Thickness: 0.8mm – 1.2mm GI or SS
Finish Coating: 50–70 microns powder coat
Pharmaceutical cleanrooms
Commercial buildings
Hospitals & operation theatres
Manufacturing industries
Warehouses & logistics units
Schools, hotels, malls, offices
Public assembly buildings
Additional Information: