Product Details:
| Minimum Order Quantity | 1 Piece |
| Cooling Capacity | 15000 CFM |
| Type | Double Skin Air Handling Unit |
| Country of Origin | Made in India |
| Service Location | Pan India |
| Payment mode | Online /Offline |
| Service Mode | Offline |
| BRAND | LENNOX |
| Frame Structure | ALUMINIUM |
| Material | Galvanized Iron |
A Pharma Air Handling Unit is a specialized HVAC equipment designed to supply clean, temperature-controlled, and humidity-controlled air to pharmaceutical cleanrooms. It ensures compliance with GMP, WHO, EU-GMP, ISO-14644, and FDA standards for critical manufacturing areas.
⭐ 1. Construction & HousingDouble Skin AHU Cabinet
Outer & Inner Skin: GI powder-coated / SS 304 (optional)
Casing Insulation: 25/43 mm PUF or Rockwool
Thermal break profile for no condensation
Air-tight, low-leak design as per ISO & GMP norms
Base Frame: Heavy-duty GI / MS powder coated
Access Doors: Insulated, gasket sealed, with vision panels
Three-stage or multi-stage filtration system:
Pre Filter (10 µ / EU4)
Removes larger dust particles
Fine Filter (5 µ / EU7 / F7)
Captures medium-size particles
HEPA Filter (0.3 µ / H13–H14)
99.97% / 99.997% efficiency
Installed at terminal or within AHU plenum
Centrifugal DIDW blower
Statically & dynamically balanced
Direct drive / Belt drive as required
Efficiency: IE2 / IE3 motor
Low noise, vibration-free performance
Chilled Water Coil / DX Coil
Copper tubes with aluminum fins
3, 4, 6, or 8 row options
SS drain pan with proper slope
Differential pressure gauges
Temperature & humidity sensors
VFD for motor speed control
BMS/SCADA interface (optional)
UV lamp (optional) for microbial control
Temperature: 18–25°C
Humidity: 45–65% RH
Air Changes: 15–60 ACH (depends on cleanroom class)
Cleanroom Classes: ISO-5 to ISO-8 / Grade A to D
Recirculation type
Fresh air / makeup air AHU
Dehumidification AHU
Terminal HEPA AHU
Laminar Flow AHU (LAF AHU)
Tablet & capsule manufacturing
Sterile formulation areas
Cleanrooms (ISO-5/6/7/8)
Injectable filling rooms
HVAC for warehouses & packing areas
API and OSD facilities
Additional Information:
Product Details:
| Minimum Order Quantity | 5 Piece |
| Capacity | 40000 CFM |
| Cooling Capacity | 40000 CFM |
| Type | Double Skin Air Handling Unit |
| Material | PPGI |
| Country of Origin | Made in India |
| Brand | Lennox |
A Floor Mounted Air Handling System is a high-performance HVAC unit designed for large industrial, commercial, and cleanroom applications. Installed directly on the floor, this AHU provides high airflow capacity, efficient air filtration, cooling/heating, and precise control of indoor air quality.
It is built with a robust double-skin insulated structure and offers flexible configurations to suit various airflow and environmental requirements. The system includes filtration stages, cooling/heating coils, blowers, dampers, and access panels for easy maintenance.
Key Features:
• Heavy-duty floor-mounted design for high airflow
• Double-skin insulated panels (PUF or Rockwool)
• Multi-stage filtration: pre-filter, fine filter, optional HEPA filter
• Chilled water/DX cooling coils and heating options
• High-efficiency, dynamically balanced blower and motor
• Fresh air, return air, and mixing box options
• Large access doors for easy service and inspection
• Low noise, energy-efficient operation
• Durable, corrosion-resistant construction
Applications:
• Pharmaceutical & biotech industries
• Hospitals and healthcare facilities
• Food & beverage processing units
• Industrial manufacturing plants
• Cleanrooms and controlled environments
A Floor Mounted Air Handling System ensures reliable performance, consistent airflow, and superior indoor air quality for demanding industrial and commercial applications.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Type | Double Skin |
| Material | Aluminium |
| Installation Type | PUF |
| Brand | LENNOX |
| Usage/Application | Pharma |
| Capacity | 2000 CFM |
| Control | ELECTRICAL |
| Energy Saving | OPTIMUM DESIGN |
| Air Flow Range | 40000 CFM |
| Driven Type | BELT/DIRECT |
An Air Handling Unit (AHU) is a central HVAC system component designed to condition, filter, cool, heat, mix, and distribute air in industrial, commercial, hospital, and cleanroom environments. AHUs ensure proper air quality, temperature, and humidity by integrating fans, coils, filters, and controls within a single unit.
⭐ 1. ConstructionType: Single Skin / Double Skin (25 mm or 43 mm PUF / Rockwool Insulation)
Outer & Inner Panels: GI powder-coated / Aluminium / SS 304
Frame: Aluminium extruded profile with thermal break construction
Base Frame: GI / MS powder-coated heavy-duty base
Access Doors: Hinged, insulated, with view glass (optional)
DIDW centrifugal fan
Forward curved / backward curved
Belt-driven or direct drive / EC plug fan
Vibration isolators (rubber pads or spring type)
Chilled water coil / DX coil / Heating coil
Copper tubes with aluminium fins
SS 304 double-slope drain pan
Pre Filter: G4 (10 micron / 90%)
Fine Filter: F7–F9 (optional)
HEPA Filter: H13/H14 (optional, for cleanrooms)
Fresh air, return air, and exhaust air dampers
Motorized actuators (optional)
Starter panel / VFD panel
Temperature & humidity sensors
Safety cut-offs
BMS compatible controls (optional)
Air Volume: 1,000 CFM to 60,000+ CFM
Static Pressure: 40 mm to 1000 mm WG
Cooling Capacity: As per project requirement
Noise Level: < 65 dB (depending on fan type)
EC plug fan high-efficiency system
UV-C germicidal lamps
Heat recovery wheel / Plate heat exchanger
Sound attenuator section
Humidifier section (steam / evaporative / ultrasonic)
Double-skin insulated base frame
Pharmaceutical cleanrooms
Hospitals and OTs
Commercial buildings
Food & beverage industries
Industrial ventilation
Data centers
Warehouses
Laboratories
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Capacity | 5000 CFM |
| Control | YES |
| Energy Saving | YES |
| Frame Structure | ALUMINIUM |
| Country of Origin | Made in India |
| BRAND | LENNOX |
We are a leading Double Skin Air Handling Unit (AHU) Manufacturer, providing high-performance, energy-efficient, and durable air handling solutions for commercial, industrial, and cleanroom applications. Our AHUs are designed to deliver optimum indoor air quality with precise control over temperature, humidity, and ventilation.
1. Product OverviewOur Double Skin Air Handling Units are engineered using a heavy-duty aluminum profile structure with PUF/PIR insulated sandwich panels. The double-skin design ensures thermal efficiency, low noise, minimal leakage, and superior durability, making them ideal for critical environments such as hospitals, pharma facilities, and industrial process areas.
2. Construction & BodyDouble Skin Panels: 25/43/50 mm PUF or PIR insulation.
Outer & inner sheet made of GI / Aluminum / SS 304.
Thermal break profiles to prevent condensation.
Modular, corrosion-resistant design for easy installation and service.
DIDW forward/backward curved centrifugal fans or plug fans.
High-efficiency AC/EC motors.
Belt-driven or direct-drive system based on airflow requirements.
Anti-vibration mountings and flexible connectors for silent operation.
Multi-stage filtration to ensure high air purity:
Pre Filter (G4 / EU4) – 90% efficiency
Fine Filter (F5–F9) – 95% efficiency
HEPA Filter (H13/H14) – 99.97% efficiency at 0.3 microns (optional)
Optional Activated Carbon Filter for odor control
Copper tubes with aluminum fins for high heat transfer.
Chilled Water (CW) / DX Cooling Coils.
Hot water/Steam heating coils as per requirement.
SS 304 sloped drain pan to prevent water stagnation.
Electric steam humidifier
Spray-type humidifier
Desiccant or cooling-based dehumidification
VFD for energy-efficient motor control
Temperature, humidity, and airflow sensors
Differential pressure gauges for filters
Panel-mounted electrical control system
BMS/PLC integration available
Airflow capacity: 500 CFM to 100,000+ CFM
Low leakage design as per international standards
Suitable for 24/7 operations in industrial and HVAC systems
Our Double Skin AHUs are used in:
Pharmaceutical cleanrooms
Hospitals & Healthcare
Food & Beverage industry
R&D laboratories
Commercial buildings, malls, offices
Industrial ventilation systems
Data centers, server rooms
Product Details:
| Minimum Order Quantity | 5 Piece |
| Capacity | 20000 CFM |
| Control | yes |
| Energy Saving | yes |
| Frame Structure | iron |
| Mode Of Service | yes |
| Country of Origin | Made in India |
Additional Information:
Product Details:
| Type | Double Skin |
| Installation Type | Floor Mounted |
| Brand | Lennox |
| Usage/Application | Industrial |
| Frequency | 50-60 Hz |
| Material | MS |
| Airflow | 1000-15000m3/h |
| Maximum working pressure of coil | 1.6 Mpa |
| Operating Voltage | 380/400 V |
Other details:
Air Handling Units (AHUs) also known as Air handlers are used to supply and circulate air around a building, or to extract stale air as part of a building’s Heating, Ventilating and Air Conditioning (HVAC) system.
Basically, an Air Handling Unit system includes a large insulated metal box that contains a fan, heating and/or cooling elements, filters, sound attenuators and dampers. In most cases, the AHU is connected to air distribution ductwork; alternatively, the AHU can be open to the space it serves
Supply air passing through the AHU is filtered and is either heated or cooled, depending on specified duty and the ambient weather conditions. In some buildings, Air Handling Units are used only to supply fresh air for ventilation and extract stale air.
For heating or cooling, AHUs may be connected to central plant such as boilers or chillers, receiving hot or chilled water for heat exchange with the incoming air. Alternatively, heating or cooling may be provided by electric heating elements or direct expansion refrigeration units built into the air handler.
When AHU systems are used to extract stale air from the building, a controlled proportion of this air may be recirculated to avoid having to condition all supplied air. AHUs can also incorporate heat recovery mechanisms to extract heat from the air being expelled and use it to heat incoming supply air
Air Handling Units vary considerably in size, capacity and complexity, depending on the job they are designed to perform
Product Details:
| Minimum Order Quantity | 1 Piece |
| Material | Galvanized Iron |
| Type | AHU |
| APPLICATION | PHARAMA, HOSPITAL, LABORATORIES, COMMERCIAL BUILDING |
| BRAND | LENNOX |
| CATEGORIES | AHU, DUCTING, CLEANROOMS PANELS & DOORS, CLEAN ROOM EQUIPEMENTS, EPOXY FLOORING |
A Heating, Ventilation, and Air Conditioning (HVAC) system is a mechanical system designed to provide thermal comfort and maintain acceptable indoor air quality within a building. It regulates temperature, humidity, and air movement while filtering and conditioning the air supplied to occupied spaces.
1. HeatingThe heating component raises indoor temperature during cold conditions. Common heating systems include:
Furnaces (gas, oil, electric)
Boilers (hot water or steam)
Heat pumps
Electric resistance heaters
Heat is distributed through:
Air ducts (forced-air systems)
Hydronic piping (radiators or radiant floor systems)
Ventilation ensures the controlled exchange of indoor and outdoor air, diluting contaminants and maintaining healthy air quality. Ventilation may be:
Natural (windows, vents)
Mechanical (fans, air handlers)
Mechanical ventilation often includes:
Exhaust fans
Supply fans
Energy recovery ventilators (ERV) or heat recovery ventilators (HRV)
Cooling equipment removes heat and moisture from the indoor air. Typical cooling equipment includes:
DX (direct expansion) systems
Chillers
Heat pumps
Split systems and packaged rooftop units
Cooling is distributed via ducted air-handling units or fan-coil units.
4. Air Distribution SystemAir handling and distribution components include:
Air Handling Units (AHUs)
Ductwork
Diffusers, grilles, and registers
Variable Air Volume (VAV) boxes
Filters (MERV-rated or HEPA for high filtration)
These components move conditioned air throughout the building and ensure uniform comfort.
5. Controls and AutomationModern HVAC systems use automated control systems such as:
Thermostats
Building Management Systems (BMS)
Sensors (temperature, humidity, CO₂, pressure)
Controls optimize performance, energy use, and occupant comfort.
6. Additional ComponentsDepending on the building, the system may include:
Humidifiers/Dehumidifiers
UV-C air purification
Economizers
Zoning systems
Additional Information:
Product Details:
| Minimum Order Quantity | 10 Piece |
| Airflow | 3000 CFM |
| Color | Blue |
| Size | Large |
| I Deal In | New Only |
| Floor Mounted | Yes |
| Automation Grade | Yes |
An Air Handling Unit (AHU) is a central component of an HVAC (Heating, Ventilation, and Air Conditioning) system, designed to condition and circulate air within a building. It helps maintain indoor air quality, temperature, and comfort by managing airflow and performing several key functions.
Key Functions of an AHUAir Circulation
Moves air throughout the building using supply and return fans.
Filtration
Removes dust, pollutants, and contaminants through filters (e.g., pre-filters, HEPA filters).
Heating and Cooling
Uses coils—typically fed by hot water, steam, or chilled water—to adjust the air temperature.
Humidity Control
Adds or removes moisture through humidifiers or dehumidification processes to maintain proper indoor humidity.
Ventilation
Mixes outdoor (fresh) air with return air, ensuring adequate fresh air supply and reducing CO₂ levels.
Air Distribution
Delivers conditioned air through ductwork into different spaces.
Housing/Enclosure – Insulated casing that contains all AHU components.
Fans (Supply/Return/Exhaust) – Move air in and out of the unit and building.
Filters – Trap dust, allergens, and airborne particles.
Heating Coil – Warms the air (hot water, electric, or steam powered).
Cooling Coil – Cools and dehumidifies air (usually chilled water or refrigerant).
Humidifier/Dehumidifier – Manages moisture levels.
Mixing Box – Blends return air with outdoor air.
Dampers – Control airflow direction and volume.
Controls & Sensors – Regulate temperature, humidity, airflow, and pressure.
Packaged AHU – Factory-built with all components integrated.
Modular AHU – Custom-built to suit large or complex installations.
Rooftop AHU (RTU) – Installed on roofs, often with integrated cooling/heating.
Terminal Units / Fan Coil Units (FCU) – Smaller, localized units (sometimes considered part of AHU family).
Commercial buildings
Hospitals and cleanrooms
Industrial facilities
Shopping malls
Airports
High-rise residential complexes
Additional Information:
Product Details:
| Minimum Order Quantity | 5 Piece |
| Airflow | 3000 CFM |
| Control | yes |
| Type | Single Skin Air Handling Unit |
| Energy Saving | yes |
| Frame Structure | Aluminium |
| Material | PPGI |
| Phase | 3 |
| Color | Blue |
| Size | Large |
| Operation Temperature | Customized |
| I Deal In | New Only |
| Floor Mounted | Yes |
| Country of Origin | Made in India |
A Floor Mounted Air Handling Unit is a centralized HVAC equipment designed to condition, filter, cool, or heat the air and distribute it to different spaces. It is typically installed on the floor in plant rooms, technical areas, or service corridors, offering high air volume capacity and easy maintenance access.
⭐ 1. ConstructionType: Floor Mounted Double Skin Air Handling Unit
Casing:
Double Skin Construction, 25/43 mm PUF or Rockwool insulation
Internal & External Sheets: GI Powder Coated / Aluminium / SS 304
Thermal Break Profile: Extruded aluminium frame with corner joints
Access Doors: Hinged / double-skin insulated with view glass (optional)
Base Frame: Heavy-duty GI / MS powder-coated / Aluminium
Air Volume: 1,000 CFM to 60,000+ CFM
Static Pressure: Up to 250 mm to 1000 mm WG
Application: Cleanrooms, Pharma, Hospitals, Commercial Buildings, Industries
DIDW (Double Inlet Double Width) centrifugal fan
Forward curve / backward curved
Belt-driven or Direct Drive EC/Plug fan
Vibration isolation pads or spring isolators
Copper tubes with aluminium fins (hydrophilic options available)
3–8 row cooling / heating coils
Chilled water / DX coil compatible
SS 304 drain pan (double slope)
Primary Pre-Filter: G4 (10 µ / 90% efficiency)
Fine Filter: F7–F9
HEPA Filter: H13/H14 (99.97%–99.997% @ 0.3 µ) (optional)
Fresh air, return air, and exhaust air dampers
Motorized actuators (optional)
On/Off switch
VFD for fan speed control (optional)
Temperature humidity sensors (optional)
Safety interlocks
EC plug fan for energy efficiency
UV-C lamps for microbial control
Heat recovery wheel / Plate heat exchanger
Sound attenuators
Built-in humidifier (steam / ultrasonic)
BMS integrable sensors
Pharmaceutical cleanrooms
Hospitals and OTs
Food & beverage industries
Commercial buildings
Industrial ventilation
HVAC central systems
Additional Information:
Product Details:
| Airflow | 3000 CFM |
| Cooling Capacity | 35000 CFM |
| Material | PPGI |
| Type | Floor Mounted |
| Phase | 3 PH |
| Compressor Type | Scroll |
| Room Type | Commercial Space |
| Country of Origin | Made in India |
An Industrial Air Handling Unit (AHU) is a key component of HVAC systems designed to condition, control, and circulate air within industrial, commercial, and clean room environments. It ensures proper temperature, humidity, filtration, and air distribution to maintain a safe and controlled workspace.
The AHU consists of sections for air filtration, heating or cooling coils, humidification/dehumidification, and a high-efficiency blower system. The unit pulls in fresh or return air, filters it to remove dust and contaminants, adjusts the air temperature and humidity as required, and delivers clean, conditioned air into the facility.
Main Features:
• Double Skin PUF/ Rockwool insulated panels
• High-efficiency pre-filters, fine filters, and optional HEPA filters
• Cooling/Heating coils (DX or Chilled Water)
• Dynamically balanced blower and low-noise motor
• Fresh air, return air, and mixing box options
• Access doors for easy maintenance
• Durable, corrosion-resistant construction
Applications:
• Pharmaceutical & Biotechnology Clean Rooms
• Food and Beverage Processing Areas
• Hospitals and Healthcare Facilities
• Industrial Production Units
• HVAC & Ventilation Systems
An Industrial AHU is designed for continuous, reliable performance—ensuring high air quality, consistent airflow, and energy-efficient operation in demanding industrial environments.
Product Details:
| Minimum Order Quantity | 1 Piece |
| Airflow | 3000 CFM |
| Frame Structure | Aluminium |
| Static Pr | @165 |
| Size | Large |
| I Deal In | New Only |
| Floor Mounted | Yes |
| BRAND | LENNOX |
| CFM | 3000 CFM |
An Air Handling Unit (AHU) is a central component of an HVAC system designed to condition, filter, control, and distribute air within commercial, industrial, and cleanroom environments. The AHU ensures proper ventilation, maintains indoor air quality, and provides temperature and humidity control based on application requirements.
1. Construction & BodyFabricated using high-quality GI / Aluminum / SS 304 panels.
Double skin construction with polyurethane/PIR insulation (25–50 mm).
Thermally broken profile to prevent heat loss and condensation.
Heavy-duty base frame made of GI / MS with powder coating.
Modular design for easy installation and maintenance.
Designed to remove dust, contaminants, and microorganisms depending on application:
Pre-Filter (EU4 / G4): 90% efficiency down to 10–5 microns.
Fine Filter (EU7 / F7): 95% down to 3 microns (optional).
HEPA Filter (H13/H14): 99.97% efficiency at 0.3 microns (for cleanrooms).
Activated Carbon Filter for odor removal (optional).
Filter mounting frames with gaskets to ensure zero leakage.
Centrifugal DIDW forward/backward curved fans or plug fans.
High-efficiency EC / AC motors, belt-driven or direct-driven.
Factory-balanced blower for low vibration and silent operation.
Vibration isolators and flexible canvas connections included.
Chilled water (CW) or DX coil for cooling.
Copper tubes with aluminum fins arranged in multiple rows for high heat transfer.
Steam or hot water heating coils as per requirement.
Drain pan made of SS 304 with proper slope for condensate removal.
Steam injection humidifier.
Spray-type humidifier.
Desiccant or cooling-based dehumidification systems.
Temperature sensors, humidity sensors, and airflow switches.
VFD (Variable Frequency Drive) for fan speed control.
Differential pressure gauges for all filters.
Motor protection and control panel as per electrical standards.
BMS/PLC compatibility for automation.
Designed for airflow capacity ranging from 500 CFM to 100,000+ CFM.
Ensures proper ventilation and maintains desired:
Temperature
Relative humidity
Cleanliness level
Fresh air ratio
Suitable for continuous 24/7 operation with minimal maintenance.
AHUs are widely used in:
Pharmaceutical clean rooms
Hospitals & Operation Theaters
Food & Beverage industries
Industrial process areas
Commercial buildings & malls
Research laboratories
HVAC ventilation systems
Product Details:
| Minimum Order Quantity | 10 Piece |
| Capacity | 3000 CFM |
| Material | Stainless Steel |
| Installation Type | PUF |
| Brand | LENNOX |
| Type | Double Skin |
A Ceiling Suspended Air Handling Unit (AHU) is a compact HVAC unit designed for areas with limited floor space. It is mounted directly to the ceiling and provides efficient air filtration, cooling, heating, and circulation in cleanrooms, laboratories, hospitals, and commercial spaces.
The unit is engineered with a slim, low-height design that fits easily above false ceilings while delivering high performance and silent operation. It ensures controlled temperature, humidity, and clean airflow without occupying floor area.
Key Features:
• Compact, low-height design suitable for false ceilings
• Double-skin insulated panels for thermal and acoustic performance
• High-efficiency pre-filters and fine filters
• Chilled water/DX cooling coil options
• Dynamically balanced blower with low-noise operation
• Easy-access service panels for maintenance
• Lightweight, corrosion-resistant construction
• Energy-efficient motors and fan systems
Applications:
• Pharmaceutical cleanrooms
• Modular labs and research facilities
• Hospitals & healthcare spaces
• Commercial HVAC systems
• Food processing and packaging areas
A Ceiling Suspended AHU is ideal where space is limited but high-quality air handling and reliable performance are required.
Product Details:
| Minimum Order Quantity | 1 Piece |
| Capacity | 5000 CFM |
| Type | Single Skin |
| Installation Type | Floor Mounted |
| Brand | Lennox |
| Usage/Application | Industrial |
| Phase | Single Phase |
| Air Flow range | 800 to 10000 m3/h |
| Material | Mild Steel |
| Frequency | 50/60 Hz |
| Voltage | 380 V |
| Country of Origin | Made in India |
| Warranty | 1 Year |
A Single Skin Air Handling Unit is an HVAC unit designed to circulate, filter, cool, or heat air in various industrial, commercial, and ventilation applications. Unlike double-skin AHUs, single-skin units have a single-layer sheet metal construction, making them more economical and ideal for non-critical environments.
⭐ 1. ConstructionType: Single Skin AHU (Floor Mounted / Ceiling Suspended)
Casing Material: GI Sheet / Aluminium / SS Sheet (0.8–1.2 mm)
Insulation (Optional):
Internal acoustic insulation (10–25 mm)
Rockwool / Nitrile rubber (if required)
Frame: Aluminium profile / MS powder-coated frame
Access Doors: GI/Aluminium with gasket sealing
Air Capacity: 1,000 CFM to 25,000+ CFM
Static Pressure: 40 mm to 80 mm WG (typical)
Usage: Ventilation, office areas, industrial rooms, warehouses, utility spaces
DIDW (Double Inlet Double Width) centrifugal fan
Forward curve / backward curved
Belt-driven or direct drive
Vibration isolators (rubber pads)
Primary Pre-Filter: G4 (90% down to 10 micron)
Fine Filter: F5–F7 (optional)
Chilled water / hot water coil
Aluminium finned copper tube coil
SS 304 drain tray
Fresh air and return air dampers
Aluminium / GI construction
Manual or motorized
On/Off switch
Overload protection
VFD (optional)
Lightweight and easy to install
Cost-effective design for general ventilation
Low to medium static pressure
Easy maintenance
Energy-efficient fans available
Compatible with ducts or free-blowing applications
Office ventilation
Industrial workshops
Utility rooms
Warehouses
Commercial buildings
Parking areas
Restaurants & hotels
Non-critical HVAC zones
Additional Information:
Product Details:
| Minimum Order Quantity | 5 Piece |
| Capacity | 80000 CFM |
| Material | PCGI |
| Door Finishing | Powder Coated |
| Height | 4 |
| Brand | LENNOX CLEAN AIR TECHNOLOGIES |
| Color | RAL 5018 |
| Panel Thickness | 50 |
| Country of Origin | Made in India |
| Filter | 3 Stage of filters |
A Double Skin Air Handling Unit (Double Skin AHU) is a type of AHU designed with two layers (skins) of metal panels separated by insulation. This construction provides better thermal performance, strength, noise reduction, and hygiene, making it ideal for commercial buildings, hospitals, pharmaceutical industries, and cleanrooms.
What “Double Skin” MeansThe AHU casing walls are made of:
Inner sheet (usually galvanized steel or stainless steel)
Outer sheet (galvanized steel, aluminum, or powder-coated steel)
Insulation layer between them (typically PUF/PIR/EPS or mineral wool)
Typical insulation thickness: 25 mm, 40 mm, or 50 mm, depending on application.
Key Features of a Double Skin AHU 1. Thermal InsulationThe insulated double-wall prevents:
Heat gain/loss
Condensation
Energy wastage
This ensures stable temperature and humidity control.
2. Better Structural StrengthThe dual panels and insulated core make the AHU:
More rigid
Less prone to vibration
Suitable for larger units or rooftop installations
Insulation between panels reduces:
Fan vibration noise
Airflow noise
Mechanical sound transmission
Ideal for areas requiring quieter operation (hospitals, labs, offices).
4. Hygienic DesignMany double-skin AHUs include:
Smooth internal surfaces
Easy-clean panels
Food/pharma-grade materials
This makes them suitable for cleanrooms and pharmaceutical applications.
5. Reduced Air LeakageBetter sealing at joints ensures:
High energy efficiency
Maintained pressure levels
Compliance with AHRI/Eurovent standards
Double-skin insulated panels
Supply and return fans
Filters (Pre-filter, Fine filter, HEPA depending on application)
Cooling coil
Heating coil
Mixing box with dampers
Humidifier or dehumidifier
Drain pan
Vibration isolators
Electrical and control panel
High durability
Long service life
Better insulation compared to single-skin AHUs
Lower noise levels
Energy-efficient and eco-friendly
Suitable for sensitive environments (pharma, biotech, healthcare)
Hospitals
Pharmaceutical units
Commercial spaces
Data centers
Industrial buildings
Cleanrooms
IT parks and malls
Hotels and auditoriums
Additional Information: